Efficiency of the refrigerant cycle is affected by the operations of the condenser. Of the
following, a more efficient centrifugal compressor operation results from: - Answers-
Lowering the condensing pressure

The heat removed from the refrigerant in a condenser is: - Answers-Sensible and latent
heat

The refrigerant unit that you have been assigned to is being taken out of service for a
major repair. You have been assigned to withdraw refrigerant for storage in suitable
containers. According to the NYC Fire Code, you must ensure that the containers: -
Answers-Are approved by the US Dept. of Transportation

The type of refrigerant system that is least likely to leak refrigerant into the building
space that are being cooled: - Answers-Indirect system

The suction pressure of a reciprocating compressor is 65 PSIG. The discharge pressure
of this compressor is 120 PSIG. The atmospheric is 14.7 PSI. The compression ratio for
the given condition is closest to: - Answers-1.69

A superheated vapor is: - Answers-Dry vapor above the saturation temperature

A refrigerant engineer verifies that a condenser water pump is cavitating. Of the
following, the most likely cause for this condition is: - Answers-A faulty cooling tower
water level controller

A centrifugal water pump is known as a lift pump when the: - Answers-The water supply
to the pump suction inlet is below the pump level

A TXV is used to maintain constant: - Answers-Evaporator superheat

The chilled water supply to the building is 55 deg F. If the chiller is being used for human
comfort, should you be concerned about this, and why? - Answers-Yes, this temp is too
high for human comfort purposes

The packing gland of a centrifugal pump serves to: - Answers-The drip part of the
packing gland gives evidence that there is water in the pump

Capacity control of reciprocating hermetic compressor is typically achieved through: -
Answers-Operation of the hot gas bypass valve

The most important reason to sub-cool the refrigerant in the condenser is to ensure that:
- Answers-A pure liquid refrigerant will enter the metering device

,A refrigeration engineer is logging readings from a reciprocating system. Compressor
discharge temperature have dropped significantly and the suction line pressure is high.
Which of the following that may be causing this set of condition? - Answers-An
expansion valve that is open too wide

Which of the following best describes how the cylinder unloader works? - Answers-Keep
in the suction valve opened while the compressor is in the return stroke

In most semi-hermetic compressors, the suction vapor is used to: - Answers-Cool the
motor

The amount of refrigerant that flows through the orifices of an economizer is determined
by the: - Answers-Differences between the high side and low side pressure

The installation of an inline refrigerant cleaning system is advisable: - Answers-To
remove impurities from the system

A low side float valve is used to maintain: - Answers-The level of the refrigerant in the
evaporator

Regarding fire safety, which ASHRAE refrigerant safety classification indicates no
flammability and lower toxicity? - Answers-A1

When an expansion valve is operating properly, at the end of the evaporator will
contain: - Answers-Only superheated vapor

What information is not contained in a Material Safety Data Sheet? - Answers-Cost of
the material

In a steam turbine, what is the function of the Kingsbury thrust bearing? - Answers-
Maintain axial positioning of the rotor shaft

A centrifugal water pump is considered to the fully primed when? - Answers-The pump
is full of liquid

Copper tubing refrigerant lines must be installed for a new system. It is a well known
service practice that tubing collapses at bends that must be made, the refrigerant
engineer should use? - Answers-Level type tubing bender

A reciprocating compressor is making a knocking sound during operation. If the
refrigerant worn parts are not causing the knocking, what probably the cause? -
Answers-Slugging of the liquid refrigerant

In order for a refrigerant to become superheated, it must be heated in a section of the
low side refrigerant line: - Answers-Where no liquid refrigerant is present

, All liquid has been recovered from a system to be overhauled, the system: - Answers-
Should not be opened until all vapor has been recovered

When a refrigerant engineer uses a portable compressor recovery unit to remove vapor
refrigerant from a refrigeration system the removal rate of the refrigerant will gradually
slow down because? - Answers-The compressor efficiency is decreasing

You are the engineer running a 2000-ton (steam driven turbine) centrifugal refrigeration
system, a refrigeration system supplies chilled water to a college campus with multiple
buildings. During the course of making your rounds, you check the 9 cell cooling tower
on the roof. You note the water level in all of the cooling tower cells is very low. Which
one of the following immediate actions would take? - Answers-Add additional make up
water to the cooling tower

A rooftop water cooling tower is connected to a water pump in the building basement
with a 12 inch diameter pipe. With the pipe turned off, a pressure gauge at the pumps
inlet show a pressure of 140 PSIG the height of the water column, in feet, would be
closest to: - Answers-323

What device protects the steam turbine from excessive speed? - Answers-Governor
assembly

A refrigeration compressor has failed to turn on. The refrigeration engineer on duty
verifies that the electrical circuit to the motor, including all switches and circuit breakers,
is complete according to recommended service practice, the next item to be checked
would likely be the: - Answers-Temperature and pressure controls

Refrigerants are characterized by their physical properties included flashpoint,
refrigeration effect, and others. Of the refrigerants in commercial and industrial, the one
with the highest latent heat and refrigerant effect is: - Answers-Ammonia

Of what characteristics is ASHRAE refrigerant safety group classification system: -
Answers-Flammability and toxicity

Of the following, an example of an in line refrigerant cleaning system that may be used
with a centrifugal compressor containing R-123 refrigerant is: - Answers-Recycling

Information about the physical and chemical properties of a hazardous material can be
found in: - Answers-Material Safety Data Sheet

What is the function of the turbine auxiliary oil pump? - Answers-Establish oil pressure
during turbine start up

The rupture disc for a low pressure centrifugal refrigeration machine is normally located
on the: - Answers-Compressor suction

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

83637 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart