100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Journeyman Electrician (2024/25Nec) With complete solution | Latest. $10.99   Add to cart

Exam (elaborations)

Journeyman Electrician (2024/25Nec) With complete solution | Latest.

 10 views  0 purchase
  • Course
  • Journeyman Electrician
  • Institution
  • Journeyman Electrician

Journeyman Electrician (2024/25Nec) With complete solution | Latest.

Preview 2 out of 8  pages

  • August 15, 2024
  • 8
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Journeyman Electrician
  • Journeyman Electrician
avatar-seller
STUVATE
Journeyman Electrician (2024/25Nec)
With complete solution | Latest.
Conductors with _____ marked on the insulation are NOT approved for use in a wet II II II II II II II II II II II II II II



location.
II



a. THW II



b. THHW II



c. THHN II



d. THWN - THHN
II II II II II



As shown in Table 310.104(A), conductors with THHN insulation are approved for use in
II II II II II II II II II II II II II



dry and damp locations only and conductors with THWN, THHW, and THW insulation are
II II II II II II II II II II II II II II



recognized for use in dry and wet locations.
II II II II II II II II




Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a
II II II II II II II II II II II II II II II II II



120/240 volt, single-phase, electrical system from the local utility company. What is the
II II II II II II II II II II II II II



MINIMUM size aluminum THW conductors required for use as service-entrance
II II II II II II II II II II



conductors for this residence?
II II II II



a. 1/0 AWGII II



b. 4/0 AWGII II



c. 3/0 AWGII II



d. 2/0 AWG - 4/0 AWG
II II II II II II II



Section 310.15(B)(7)(1) permits one-family dwelling 120/240 volt, single-phase, service-
II II II II II II II II



entrance conductors to be sized at an ampacity of not less than 83% of the service rating.
II II II II II II II II II II II II II II II II



Therefore, 200 amperes x 83% = 166 amperesTable 310.15(B)(16) indicates size 4/0
II II II II II II II II II II II II



AWG THW aluminum conductors with an allowable ampacity of 180 amperes should be
II II II II II II II II II II II II II



selected for this dwelling.
II II II II




Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is
II II II II II II II II II II II II II II



installed at a multi-family dwelling, the full-load current rating, in amperes, of the
II II II II II II II II II II II II II



secondary is _____.
II II II



a. 625 amperes
II II



b. 265 amperes
II II



c. 526 amperes
II II



d. 1250 amperes - 625 ampreres
II II II II II II II



To find the full-load current rating of the single-phase transformer apply the single-phase
II II II II II II II II II II II II



current formula as shown:
II II II II



I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes
II II II II II II II II II II II II II




Which one of the following listed circuit breakers is NOT a standard ampere rating?a. 75
II II II II II II II II II II II II II II II II



amperes
II



b. 90 amperes
II II



c. 110 amperes
II II



d. 225 amperes - 75 amperes
II II II II II II II

, Table 240.6(A) illustrates the standard ampere ratings for fuses and circuit breakers. A
II II II II II II II II II II II II



circuit breaker with an ampere rating of 75 amperes is not a standard ampere rating.
II II II II II II II II II II II II II II II




The MINIMUM length of free conductor to be left at each junction box for the purpose of
II II II II II II II II II II II II II II II II II II



splicing conductors, or making connections to luminaires or devices shall be _____ .a. 4
II II II II II II II II II II II II II II



inches
II



b. 10 inches
II II



c. 8 inches
II II



d. 6 inches - 6 inches
II II II II II II II



As per Section 300.14 at least 6 in. of free conductor is to be left at each junction box for
II II II II II II II II II II II II II II II II II II II



splices or the connection of luminaires or devices. The intent of this rule is to ensure
II II II II II II II II II II II II II II II II



enough conductor slack for the terminal connections or splices to be made easily.
II II II II II II II II II II II II II




In general, overhead service-drop conductors shall NOT be smaller than _____.
II II II II II II II II II II II II



a. 2 AWG copper
II II II



b. 4 AWG copper
II II II



c. 6 AWG copper
II II II



d. 8 AWG copper - d. 8 AWG copper
II II II II II II II II II II



Section 230.23(B) requires overhead service-drop conductors to be not smaller than 8
II II II II II II II II II II II



AWG copper or 6 AWG aluminum or copper-clad aluminum. Do not get service-drop
II II II II II II II II II II II II II



conductors, the overhead conductors between the utility electric supply system and the
II II II II II II II II II II II II



service point, confused with the service-entrance conductors, the conductors from the
II II II II II II II II II II II



service point from the utility company to the service disconnecting means.
II II II II II II II II II II II




When a galvanized eye-bolt is to be used as the point of attachment for an electrical
II II II II II II II II II II II II II II II II II



service, the NEC requires the eye-bolt to be installed NOT less than _____ above finished
II II II II II II II II II II II II II II II



grade.
II



a. 8 ft.II II



b. 10 ft.
II II



c. 12 ft.
II II



d. 15 ft. - 10 Ft
II II II II II II II



The intent of Section 230.26 is to provide adequate vertical clearance of the conductors
II II II II II II II II II II II II II



and prevent physical damage to the conductors and prevent persons from making
II II II II II II II II II II II II



accidental contact with the conductors which may create a shock hazard or electrocution.
II II II II II II II II II II II II II



In no case shall the point of attachment of the service-drop conductors to be less than 10
II II II II II II II II II II II II II II II II II



ft. above finished grade.
II II II II




Why is electrical continuity required for metallic conduit?
II II II II II II II II II



a. To reduce voltage drop.
II II II II



b. To limit galvanic corrosion.
II II II II



c. To establish an effective ground-fault path and facilitate the operation of the overcurrent
II II II II II II II II II II II II II



protective device.
II II



d. To reduce electrolysis. - To establish an effective ground-fault path and facilitate the
II II II II II II II II II II II II II II II



operation of the overcurrent protective device.
II II II II II II

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller STUVATE. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67866 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.99
  • (0)
  Add to cart