Package deal
EPA 608 Bundled Exams with Complete Solution | Verified Answers | 2024
EPA 608 Bundled Exams with Complete Solution | Verified Answers | 2024
[Show more]EPA 608 Bundled Exams with Complete Solution | Verified Answers | 2024
[Show more]As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - a. July 1, 1992 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the atmosph...
Preview 4 out of 80 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - a. July 1, 1992 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the atmosph...
What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? - 
November 14, 1994 
Section 608 of the Federal Clean Air Act requires technicians to what? - Recover all refrigerants. 
The objective of the Clean Air Act is to protect what? - The earth's stra...
Preview 2 out of 7 pages
Add to cartWhat date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? - 
November 14, 1994 
Section 608 of the Federal Clean Air Act requires technicians to what? - Recover all refrigerants. 
The objective of the Clean Air Act is to protect what? - The earth's stra...
a vacuum pump should be connected - as far away from the pump as possible 
a high capacity vacuum pump and short, large diameter hoses will - dramatically reduce emissions, 
pressure drop, and evacuation/dehydration time 
ozone contains three - oxygen atoms 
one chlorine atom can destroy - 100,000 o...
Preview 2 out of 8 pages
Add to carta vacuum pump should be connected - as far away from the pump as possible 
a high capacity vacuum pump and short, large diameter hoses will - dramatically reduce emissions, 
pressure drop, and evacuation/dehydration time 
ozone contains three - oxygen atoms 
one chlorine atom can destroy - 100,000 o...
Are there drop-in replacements for R-12 systems? Why or why not? - No because the new 
refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
What type of oil is used in R-134a and what oils will it mix with? - Ester based oils and they do not 
mix with other oils 
What ty...
Preview 2 out of 11 pages
Add to cartAre there drop-in replacements for R-12 systems? Why or why not? - No because the new 
refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
What type of oil is used in R-134a and what oils will it mix with? - Ester based oils and they do not 
mix with other oils 
What ty...
As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - a. July 1, 1992 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the atmosph...
Preview 4 out of 80 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - a. July 1, 1992 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the atmosph...
Refrigeration technicians who violate the Clean Air Act can: - - Lose their EPA certification, be fined, 
be required to appear in Federal court. 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - - 
recovery and recycling. 
Refrigerant that is r...
Preview 2 out of 15 pages
Add to cartRefrigeration technicians who violate the Clean Air Act can: - - Lose their EPA certification, be fined, 
be required to appear in Federal court. 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - - 
recovery and recycling. 
Refrigerant that is r...
Recovery equipment used for the service or repair of small appliances must be certified by an EPA 
approved lab if the recovery equipment was made after - November 15, 1993 
Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances 
must be capable of: - re...
Preview 1 out of 4 pages
Add to cartRecovery equipment used for the service or repair of small appliances must be certified by an EPA 
approved lab if the recovery equipment was made after - November 15, 1993 
Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances 
must be capable of: - re...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller AmazingGrace. Stuvia facilitates payment to the seller.
No, you only buy these notes for $40.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
72042 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now